HCV-ST Oil electrical level indicators

Manufacturer:
ELESA

Material

Transparent polyamide based (PA-T) technopolymer. Highly resistant to shocks, solvents, oils with additives, aliphatic and aromatic hydrocarbons, petrol, naphtha, phosphoric esters.

Avoid contact with alcohol or detergents containing alcohol.

Screws, nuts and washers

Zinc-plated steel.

Packing rings

Step-shaped for the seal on the reservoir walls and NBR synthetic rubber O-ring under screw head.

Suggested roughness of the packing ring application surface Ra = 3 µm.

Sensor bracket

Watertight in glass-fibre reinforced polyamide based (PA) technopolymer, black colour, with MAX temperature sensor (80°C).

For a correct assembly see Warnings.

Swivelling connector

With built-in cable gland and contact holder. Front or axial output (high or low) ensuring protection against water sprays (protection class IP 65 according to table EN 60529 table-).

Contrast screen

White lacquered aluminium. The housing, in the appropriate external rear slot, guarantees the best protection from direct contact with fluid.

It can be taken out from the inclined side, before assembly to allow the insertion of level lines or words.

Standard executions

  • HCV-ST-NO: with electric contact normally open (NO).
  • HCV-ST-NC: with electric contact normally closed (NC).

Maximum continuous working temperature

90°C (with oil).

Oil electrical level indicators
More Information
Material Technopolymer