HCY-E Oil electrical level indicators

Manufacturer:
ELESA

Material

Transparent polyamide based (PA-T) technopolymer. Highly resistant to shocks, solvents, oils with additives, aliphatic and aromatic hydrocarbons, petrol, naphtha, phosphoric esters.

Avoid contact with alcohol or detergents containing alcohol.

Screws

Nickel-plated brass with hexagon socket.

Packing rings

NBR synthetic rubber O-Ring.

Float

Polyamide based (PA) technopolymer in red colour, with a built-in magnetic element to activate the electric contact when the oil level drops to the minimum set at 40mm over the screw axis (dimension l).

Sensor bracket

Watertight, black colour, with a built-in relay (reed).

For a correct assembly see Warnings.

Connector

Right side output including protection against water sprays (protection class IP 65 according to EN 60529 table-).

Contrast screen

White lacquered aluminium. The housing, in the appropriate external rear slot, guarantees the best protection from direct contact with fluid.

It can be taken out before assembly to allow the insertion of level lines or words.

Standard executions

  • HCY-E-NO: electric contact normally open that closes when the minimum level is reached.
  • HCY-E-NC: electric contact normally closed that opens when the minimum level is reached.

Maximum continuous working temperature

80°C (with oil).

Oil electrical level indicators